Help formatting eagle on VAX 11/780
dyer at atari.UUCP
dyer at atari.UUCP
Tue Feb 17 09:51:04 AEST 1987
Anybody with a VAX ever seen this? I need some help....
I am adding a new Eagle (no, not a super eagle) to a 4.2 BSD VAX
11/780 with a Systems Industries 9900 controller. It won't
format. Any comments on the following behaviour of the format
utility found on the 4.2 console media? Here's a blow-by-blow
from the console hardcopy:
| >>>H [halt, unjam and
| CPU HALTED init "just for luck"]
|
| >>>U
|
| >>>I
| INIT SEQ DONE
|
| >>>L FORMAT [load formatter...]
|
| LOAD DONE, 00004C00 BYTES LOADED
| >>>S 2 [... and run it]
| Disk format/check utility
|
| Enable debugging (0=none, 1=bse, 2=ecc, 3=bss+ecc)? 0
| Device to format? hp(9,0)
|
| HALT INST EXECUTED [almost immediately we
| HALTED AT 00000001 get a halt. Huh?]
|
| >>>
|
[hp1 --- the first eagle --- is at mba1 drive 0, which means that hp2
(the new eagle) should be at mba1 drive 1, thus the "9" above. mba1
is on tr10, and if it matters, hp0 is an RM05 way over on mba0.]
I suspect something is *really* wrong, because of the halt
instruction. You'd think it'd complain about an I/O error or
something constructive like that. Forgive my naivete. So:
o Has anyone had a similar problem?
o What was wrong?
o What did you do to fix it?
and
o Why do hardware people start to cry when programmers
take up screwdrivers and soldering irons?
--
-Landon Dyer, Atari Corp. {sun,lll-lcc,imagen}!atari!dyer
The views expressed here do not not
necessarily reflect those of Atari Corp. Segments are for worms.