extending carrier wait timeout in HDB?

Greg A. Woods woods at eci386.uucp
Fri Dec 14 07:19:59 AEST 1990


In article <936 at gnosys.svle.ma.us> gst at gnosys.svle.ma.us (Gary S. Trujillo) writes:
> Does anyone know of some way of extending the timeout for the remote
> carrier in the UNIXpc version of HoneyDanBer UUCP?

It's real easy in *any* version of the HDB-UUCP version of the BNU.

Here's what we do to over-come the excessive wait sometimes imposed by
our "phone-system" for connecting long-distance calls:

hayesne	=,-,	"" \M\p\r\pAT\r\c OK\r ATS7=60\r\c OK\r ATDT\T\r\d\d\d\d\d\d\d\d\d\d\c CONNECT \m\c

(For anyone who's news transport system munged the previous line, well,
it contains a series of '\d's, and then a '\c', immediately after the
"ATDT\T\r".)

S7 tells the Hayes (clone) modem to wait 60 seconds for carrier.  The
'\d's are 2 second delays each.  (A '\p' is only a 1/4-1/2 second pause.)
-- 
							Greg A. Woods
woods@{eci386,gate,robohack,ontmoh,tmsoft}.UUCP		ECI and UniForum Canada
+1-416-443-1734 [h]  +1-416-595-5425 [w]  VE3TCP	Toronto, Ontario CANADA
Political speech and writing are largely the defense of the indefensible-ORWELL